TEMPEST
termsecuritygovernance & riskhacking
Kept in this browser · My desk
The United States government code word for compromising emanations, and by extension the classified standards and the shielding that limit them; NIST now files the subject under emissions security (EMSEC).
Markus Kuhn and Ross Anderson describe compromising emanations as known to military organizations since at least the early 1960s, "or Tempest radiation, a code word for a U.S. government programme aimed at attacking the problem". The standards have public names and secret contents: NAG1A and FS222 in the 1950s and 1960s, NACSIM 5100 in 1970 and 5100A in 1981, and NSTISSAM TEMPEST/1-92 of 15 December 1992, while the actual limits and test procedures remain classified. NIST SP 800-53 Revision 5 asks for protection against information leakage due to electromagnetic emanations (PE-19) and notes that Emissions Security (EMSEC) policies include the former TEMPEST policies. Germany's Federal Office for Information Security (BSI) publishes lists of tested devices in four classes, Level A and Zone 1 to Zone 3.
What the word means. TEMPEST is a code word, not an acronym. Markus Kuhn's 2003 Cambridge report explains that the United States (US) military code word first named a classified government programme for studying emission security (EMSEC) problems and writing protection standards, and has since become a synonym for compromising emanations; names of classified programmes are usually random dictionary words, although many attempts to read this one as an acronym circulate. Germany's Federal Office for Information Security (BSI, Bundesamt für Sicherheit in der Informationstechnik) says the same in its glossary, a code name and not an acronym, and uses the word both for the protective measures and for the attack methods. It therefore names a problem, a programme and a market at once: the leak (data rebuilt from a machine's unintended signals), the classified test standards that measure it, and the shielded equipment, rooms and buildings that keep it below a threshold. The doctrine around it is red/black separation: equipment carrying confidential data in clear is isolated by filters and shields from equipment that handles signals going outside.
Before the name. Kuhn traces military interest to the First World War, when the German army listened to Allied field telephones through the earth-return current of single-wire lines; from 1915 the French and British moved their earth connections hundreds and later thousands of metres behind the front, adopted twisted pairs and limited what was said on field phones. The story most often told as the origin of attacks on cipher machines comes from Peter Wright's memoir Spycatcher, as Kuhn and Ross Anderson retell it: in 1960 British scientists tapped the telex cable leaving the French embassy in London, routed the signal to a room in a nearby hotel and found the plaintext riding as a faint secondary signal on the enciphered traffic. The memoir is the only source for that account.
The US standards. Their names are public and their contents are not. Kuhn lists the first national test standards, NAG1A and FS222, in the 1950s and 1960s; National Communications Security Information Memorandum (NACSIM) 5100 in 1970 and 5100A in 1981; and National Security Telecommunications and Information Systems Security Advisory Memorandum (NSTISSAM) TEMPEST/1-92, extracts of which were declassified in 1999 after a Freedom of Information Act (FOIA) request by John Young. The declassified tutorial NACSIM 5000, TEMPEST Fundamentals, names further documents, among them an acoustics test standard, NACSEM 5103, and all of them, with the North Atlantic Treaty Organization (NATO) equivalent AMSG 720B, were still classified when he wrote. A companion memorandum that the National Security Agency (NSA) released on a FOIA appeal, published by Cryptome on 30 December 2000, shows how the parts fit: NSTISSAM TEMPEST/2-95, RED/BLACK Installation Guidance, of 12 December 1995. Equipment is tested against the Level I, II or III limits of TEMPEST/1-92, and only Level I counts as TEMPEST certified; facilities are zoned under TEMPEST/2-92 by measuring how much they attenuate radiated signals in four test bands between 10 and 1,000 MHz against a reference of two antennas 20 metres apart in open field; and a Certified TEMPEST Technical Authority (CTTA), a qualified government employee, decides which countermeasures apply, with the warning that no funds should be committed without the CTTA's agreement.
Europe and NATO. NATO's current documents include SDIP-27 and SDIP-29, produced by its Communication and Information Systems Security and Evaluation Agency (SECAN); the United Kingdom's National Cyber Security Centre (NCSC) says its TEMPEST and electromagnetic security guides are based on NATO and European Union (EU) standards, and that its Implementation Guide 14 (issue 3.0, 2018) interprets SDIP-27 for national use. The Council of the EU works through Information Assurance Security Guidelines (IASG): 7-02 on zoning procedures, 7-03 on requirements and evaluation, with equipment levels A, B and C, and 7-04 on accrediting TEMPEST companies, approved by the Council Security Committee on 22 March 2019, which makes level A and B equipment subject to proliferation rules for sales outside the EU. The BSI is Germany's National TEMPEST Authority and runs a public version of the scheme: buildings are zoned by their equivalent free-space attenuation, devices are classed to match in its TL-03305 lists, and each device is tested before classified processing begins.
The civilian catalogue. The National Institute of Standards and Technology (NIST) files the subject under control PE-19, information leakage, in Special Publication 800-53 Revision 5 (2020). PE-19(1) asks for national emissions security policies and notes that EMSEC policies include the former TEMPEST policies; the errata of December 2020 removed the words "and TEMPEST" from that enhancement's title. Control AC-18(5) adds the wireless side: choose antennas and transmission power so that signals are less likely to be received outside the organization's boundaries.
How it reached civilians. Kuhn credits Wim van Eck's 1985 demonstration, a television set with manually controlled synchronization reconstructing a screen at a distance, with bringing the problem to the civilian security community; in 1998 Kuhn and Anderson's Soft Tempest showed that software can also choose what a machine broadcasts, for attack or, with filtered fonts, for defence. Open tools followed the open papers. In 2024 Santiago Fernández and colleagues at the Universidad de la República in Montevideo applied deep learning to the harder case of the High-Definition Multimedia Interface (HDMI), whose 10-bit encoding blurs the images that the analogue-era methods recover, and reported a reduction of more than 60 percentage points in the character error rate of text read from the emanations.
What goes wrong. Secrecy has a price: Kuhn noted that the military test standards remain secret and that no civilian equivalent existed, so buyers outside government cannot check a vendor's claim except through a national authority. Compliance is fragile: the BSI withdraws a device set's approval as soon as anything changes (a second monitor, a webcam, a replaced keyboard, a repair), and NSTISSAM TEMPEST/2-95 warns that a system can radiate beyond its boundary even when every component meets the limits, through cable lengths, interfaces and grounding. And shielding is only half the answer: the zoning approach exists because distance an organization controls is cheaper than hardened equipment.
Also known as: Tempest radiation, TEMPEST standards, NSTISSAM TEMPEST/1-92
Sources
- Markus G. Kuhn and Ross J. Anderson, Soft Tempest, Information Hiding 1998, LNCS 1525 (read 2026-11-23): compromising emanations or Tempest radiation, a code word for a US government programme; known to military organizations since at least the early 1960s; red/black separation
- Markus G. Kuhn, Compromising emanations, UCAM-CL-TR-577, University of Cambridge, December 2003 (read 2026-11-23): NAG1A and FS222 (1950s and 1960s), NACSIM 5100 (1970), 5100A (1981), NSTISSAM TEMPEST/1-92 (15 December 1992); limits and test procedures classified
- NIST SP 800-53 Revision 5, September 2020 (read 2026-11-23): PE-19 information leakage; PE-19(1): Emissions Security (EMSEC) policies include the former TEMPEST policies
- BSI, Availability of shielded devices (read 2026-11-23): TL-03305 lists of TEMPEST devices in the classes Level A, Zone 1, Zone 2 and Zone 3; emission test before classified processing
- NSTISSAM TEMPEST/2-95, RED/BLACK Installation Guidance, National Security Telecommunications and Information Systems Security Committee, 12 December 1995, released by the NSA on a FOIA appeal and published by Cryptome on 30 December 2000 (read 2026-11-23): supersedes NACSIM 5203 of 30 June 1982; definitions of RED and BLACK equipment, the RED/BLACK concept, compromising emanations, inspectable space, equipment and facility TEMPEST zones; physical and electrical separation; 100, 80 and 60 dB isolation; Table 3-1 separations of 50 cm and 1 m for processors and 5 cm (15 cm for parallel runs over 30 m) for lines; shielded cables and optical fibre; facility zoning in four bands from 10 to 1,000 MHz against a 20 m open-field reference; no commitment of funds without CTTA concurrence
- BSI, Emission security glossary (read 2026-11-23): TEMPEST is a code name, not an acronym, used both for the protective measures and the attack methods; EMSEC; a device set (computer, screen, mouse and keyboard) is tested and used as a unit; Level A devices process GEHEIM in zone 0, as cryptographic hardware generally must; Zone 1, 2 and 3 devices approved for zones 1 to 3, 2 and 3, and 3; the BSI is Germany's National TEMPEST Authority
- National Cyber Security Centre (UK), TEMPEST and EMS Policy (read 2026-11-23): its TEMPEST and electromagnetic security documents are based on NATO and EU standards; Implementation Guide 14 (issue 3.0, 2018) interprets SDIP-27 for UK use, with SDIP-27 and SDIP-29 produced by SECAN; Good Practice Guide 14, issue 2.3, September 2016
- Council of the European Union, doc. 7887/19, Information Assurance Security Guidelines on Accreditation of EU TEMPEST Companies (IASG 7-04), approved by the Council Security Committee on 22 March 2019, replacing doc. 16267/12 (read 2026-11-23): TEMPEST protection rests on facility zoning (IASG 7-02) and equipment testing (IASG 7-03, levels A, B and C) or on operating systems in a shielded enclosure (IASG 7-01); National TEMPEST Authorities; level A and B equipment subject to proliferation rules outside the EU
- Santiago Fernández, Emilio Martínez, Gabriel Varela, Pablo Musé and Federico Larroca, Deep-TEMPEST: Using Deep Learning to Eavesdrop on HDMI from its Unintended Electromagnetic Emanations, Universidad de la República, Montevideo, arXiv:2407.09717, 12 July 2024 (read 2026-11-23): HDMI's 10-bit TMDS encoding makes analogue-era reconstruction unreadable; a deep network trained largely on simulated samples, with a published dataset of about 3,500 samples, cuts the average character error rate by over 60 percentage points; built on gr-tempest; countermeasures discussed
- BSI, Follow-on modifications to a shielded device (read 2026-11-23): a second monitor, webcam or headset, a replaced keyboard or monitor, a repair or any change voids the assured emission characteristics; processing of VS-VERTRAULICH or higher must cease until a new emissions test