red/black separation
termsecuritycryptographygovernance & risk
Kept in this browser · My desk
The principle that equipment carrying classified information in clear (red) is isolated by filters, shielding and distance from equipment that handles signals leaving the protected area (black).
Kuhn and Anderson state it in their 1998 Soft Tempest paper: even inside shielded environments, red equipment carrying confidential data, such as computer terminals, has to be isolated by filters and shields from black equipment, such as radio modems, that handles signals going outside. The air gap is the principle taken to its limit, with no connection at all between red and black. The academic covert-channel papers are, in these terms, ways of turning a red machine into a black transmitter through an effect nobody wired: the Fansmitter paper lists the zones approach, "also referred to as the black-red separation approach", as the procedural answer to acoustic, electromagnetic and optical threats, with sensitive computers kept in areas where phones, microphones and electronic equipment are banned.
The formal definition. The United States (US) memorandum on the subject, National Security Telecommunications and Information Systems Security Advisory Memorandum (NSTISSAM) TEMPEST/2-95, RED/BLACK Installation Guidance, of 12 December 1995, defines the RED/BLACK concept as the separation of electrical and electronic circuits, components, equipment and systems that handle national security information (RED) in electrical form from those that handle non-national security information (BLACK) in the same form, and applies the two words also to the areas that contain them. RED equipment processes unencrypted classified information; BLACK equipment processes only unclassified or encrypted information; a RED or BLACK line is any wire or optical fibre that carries such a signal or starts or ends in such equipment. The memorandum superseded National COMSEC (communications security) Information Memorandum (NACSIM) 5203 of 30 June 1982; it was marked for official use only and was released by the National Security Agency (NSA) on a Freedom of Information Act (FOIA) appeal, published by Cryptome in December 2000.
Two separations. Physical separation keeps distance between RED and BLACK so that emissions from RED devices are less likely to couple into BLACK systems. Electrical separation routes every signal conductor from a RED device only to another RED device, or encrypts it before it reaches BLACK, and covers signal distribution, power distribution and grounding; switches that interface the two should isolate port to port by 100 dB across the 0.3 to 15 kHz audio band, 80 dB across video up to 5 MHz, and 60 dB from once to ten times the data rate.
How far. The memorandum's Table 3-1 sets distances by how well the equipment is suppressed (Level I, II or III of NSTISSAM TEMPEST/1-92) and how well the facility attenuates (TEMPEST zone A, B or C, or an inspectable space under 20 metres, 20 to 100 metres, or over 100 metres). The best equipment in the worst facility (recommendation A) keeps any RED processor 50 cm from BLACK equipment, from BLACK lines that leave the inspectable space or feed a radio transmitter, from BLACK power lines and from fortuitous conductors such as pipes; untested equipment in the same facility (recommendation C) needs a full metre; untested equipment in the best facility (recommendation I) needs a metre only from BLACK lines that leave or feed a transmitter. RED wire lines stay 5 cm from such BLACK lines, 15 cm for parallel runs over 30 metres, and never share a conduit with them; RED and BLACK optical fibres may share one if they are not mixed in a multifibre cable and the BLACK fibre has no metallic sheath or stiffener. Metallic cables need at least one overall braided shield of 85 to 90% coverage, terminated 360 degrees at both ends, unless that creates a ground loop, in which case one end or a fibre is preferred. The deciding person is a Certified TEMPEST Technical Authority (CTTA), and no funds should be committed without the CTTA's agreement.
Where it applies. The principle governs where cables run, which equipment may share a room or a power circuit, and where cipher equipment sits, since a cipher machine has a red side (plaintext) and a black side (ciphertext); Markus Kuhn notes that equipment with both red and black connections, such as cipher machines and multilevel secure workstations, needs particularly thorough testing. Its failure is the oldest compromising-emanations story in the literature, retold by Kuhn and Ross Anderson from Peter Wright's memoir: in 1960 British scientists tapped the telex cable leaving the French embassy in London and found plaintext leaking as a faint secondary signal on the black side of the cipher machine.
Its modern forms. Zoning is one: Germany's Federal Office for Information Security (BSI) assesses buildings by the attenuation up to the boundary of the controlled area and requires devices whose emissions are low enough for that zone, so that what leaks from the red side is too weak to be received where an attacker can stand; it also warns that power cables, air-conditioning ducts and metal pipes carry emissions out with little loss, so the organization must control that infrastructure or use the hardest devices or a filtered shielded enclosure. The air gap is another, the principle taken to its limit with no connection at all. The academic air-gap papers keep returning to it: the 2024 RAMBO paper, which leaks data from memory buses by radio, lists red/black zone restrictions first among its countermeasures, keeping radio receivers away from isolated computers or outside a radius of several metres.
Also known as: red/black principle, red-black separation, separação red/black
Sources
- Kuhn and Anderson, Soft Tempest, 1998 (read 2026-11-23): red equipment carrying confidential data isolated by filters and shields from black equipment such as radio modems
- Guri and others, Fansmitter, arXiv:1606.05915 (read 2026-11-23): the zones approach, also called black-red separation, against acoustic, electromagnetic and optical threats
- NSTISSAM TEMPEST/2-95, RED/BLACK Installation Guidance, National Security Telecommunications and Information Systems Security Committee, 12 December 1995, released by the NSA on a FOIA appeal and published by Cryptome on 30 December 2000 (read 2026-11-23): supersedes NACSIM 5203 of 30 June 1982; definitions of RED and BLACK equipment, the RED/BLACK concept, compromising emanations, inspectable space, equipment and facility TEMPEST zones; physical and electrical separation; 100, 80 and 60 dB isolation; Table 3-1 separations of 50 cm and 1 m for processors and 5 cm (15 cm for parallel runs over 30 m) for lines; shielded cables and optical fibre; facility zoning in four bands from 10 to 1,000 MHz against a 20 m open-field reference; no commitment of funds without CTTA concurrence
- Markus G. Kuhn, Compromising emanations: eavesdropping risks of computer displays, UCAM-CL-TR-577, University of Cambridge Computer Laboratory, December 2003 (read 2026-11-23): Tempest a code word, usually a random dictionary word; First World War earth-loop eavesdropping; Peter Wright's 1960 account; red/black separation, with cipher machines and multilevel workstations needing particularly thorough testing; NAG1A, FS222, NACSIM 5100 and 5100A, NSTISSAM TEMPEST/1-92 extracts declassified in 1999, NACSIM 5000, NACSEM 5103, AMSG 720B; a laptop's LVDS display link read at 10 m through three plasterboard walls
- BSI, The National Zoning Model of Emission Security (read 2026-11-23): buildings zoned by equivalent free-space attenuation to the boundary of the controlled area and devices classed to match, the two inseparable; the aim is a maximum achievable reception level at the perimeter; only metallic components shield efficiently; BSI TR-03209
- BSI, Division of buildings and properties into zones (read 2026-11-23): equivalent distances set by the controlled area; the outer walls delimit it where there is no fence; a controlled area without a sphere of at least 8 m radius is a high-risk case decided individually by the BSI; 1,000 m or more (bunker, shielding enclosure) means zone 3; power cables, air-conditioning ducts and metal pipes act as random conductors; sole control of the infrastructure, otherwise Level A devices or devices in a filtered shielding enclosure
- Mordechai Guri, RAMBO: Leaking Secrets from Air-Gap Computers by Spelling Covert Radio Signals from Computer RAM, Ben-Gurion University of the Negev, arXiv:2409.02292, 3 September 2024 (read 2026-11-23): malware generates radio signals from memory buses received with a software-defined radio; up to 1,000 bit/s; up to 700 cm at the slowest setting, 450 cm and 300 cm at faster ones with 2 to 4% bit errors; a 4,096-bit RSA key in about 42 seconds at low speed; countermeasures from red-black zone restrictions to memory monitoring, jamming and Faraday enclosures