red/black separation

term

securitycryptographygovernance & risk

Kept in this browser · My desk

The principle that equipment carrying classified information in clear (red) is isolated by filters, shielding and distance from equipment that handles signals leaving the protected area (black).

Kuhn and Anderson state it in their 1998 Soft Tempest paper: even inside shielded environments, red equipment carrying confidential data, such as computer terminals, has to be isolated by filters and shields from black equipment, such as radio modems, that handles signals going outside. The air gap is the principle taken to its limit, with no connection at all between red and black. The academic covert-channel papers are, in these terms, ways of turning a red machine into a black transmitter through an effect nobody wired: the Fansmitter paper lists the zones approach, "also referred to as the black-red separation approach", as the procedural answer to acoustic, electromagnetic and optical threats, with sensitive computers kept in areas where phones, microphones and electronic equipment are banned.

The formal definition. The United States (US) memorandum on the subject, National Security Telecommunications and Information Systems Security Advisory Memorandum (NSTISSAM) TEMPEST/2-95, RED/BLACK Installation Guidance, of 12 December 1995, defines the RED/BLACK concept as the separation of electrical and electronic circuits, components, equipment and systems that handle national security information (RED) in electrical form from those that handle non-national security information (BLACK) in the same form, and applies the two words also to the areas that contain them. RED equipment processes unencrypted classified information; BLACK equipment processes only unclassified or encrypted information; a RED or BLACK line is any wire or optical fibre that carries such a signal or starts or ends in such equipment. The memorandum superseded National COMSEC (communications security) Information Memorandum (NACSIM) 5203 of 30 June 1982; it was marked for official use only and was released by the National Security Agency (NSA) on a Freedom of Information Act (FOIA) appeal, published by Cryptome in December 2000.

Two separations. Physical separation keeps distance between RED and BLACK so that emissions from RED devices are less likely to couple into BLACK systems. Electrical separation routes every signal conductor from a RED device only to another RED device, or encrypts it before it reaches BLACK, and covers signal distribution, power distribution and grounding; switches that interface the two should isolate port to port by 100 dB across the 0.3 to 15 kHz audio band, 80 dB across video up to 5 MHz, and 60 dB from once to ten times the data rate.

How far. The memorandum's Table 3-1 sets distances by how well the equipment is suppressed (Level I, II or III of NSTISSAM TEMPEST/1-92) and how well the facility attenuates (TEMPEST zone A, B or C, or an inspectable space under 20 metres, 20 to 100 metres, or over 100 metres). The best equipment in the worst facility (recommendation A) keeps any RED processor 50 cm from BLACK equipment, from BLACK lines that leave the inspectable space or feed a radio transmitter, from BLACK power lines and from fortuitous conductors such as pipes; untested equipment in the same facility (recommendation C) needs a full metre; untested equipment in the best facility (recommendation I) needs a metre only from BLACK lines that leave or feed a transmitter. RED wire lines stay 5 cm from such BLACK lines, 15 cm for parallel runs over 30 metres, and never share a conduit with them; RED and BLACK optical fibres may share one if they are not mixed in a multifibre cable and the BLACK fibre has no metallic sheath or stiffener. Metallic cables need at least one overall braided shield of 85 to 90% coverage, terminated 360 degrees at both ends, unless that creates a ground loop, in which case one end or a fibre is preferred. The deciding person is a Certified TEMPEST Technical Authority (CTTA), and no funds should be committed without the CTTA's agreement.

Where it applies. The principle governs where cables run, which equipment may share a room or a power circuit, and where cipher equipment sits, since a cipher machine has a red side (plaintext) and a black side (ciphertext); Markus Kuhn notes that equipment with both red and black connections, such as cipher machines and multilevel secure workstations, needs particularly thorough testing. Its failure is the oldest compromising-emanations story in the literature, retold by Kuhn and Ross Anderson from Peter Wright's memoir: in 1960 British scientists tapped the telex cable leaving the French embassy in London and found plaintext leaking as a faint secondary signal on the black side of the cipher machine.

Its modern forms. Zoning is one: Germany's Federal Office for Information Security (BSI) assesses buildings by the attenuation up to the boundary of the controlled area and requires devices whose emissions are low enough for that zone, so that what leaks from the red side is too weak to be received where an attacker can stand; it also warns that power cables, air-conditioning ducts and metal pipes carry emissions out with little loss, so the organization must control that infrastructure or use the hardest devices or a filtered shielded enclosure. The air gap is another, the principle taken to its limit with no connection at all. The academic air-gap papers keep returning to it: the 2024 RAMBO paper, which leaks data from memory buses by radio, lists red/black zone restrictions first among its countermeasures, keeping radio receivers away from isolated computers or outside a radius of several metres.

Also known as: red/black principle, red-black separation, separação red/black

Sources