emission security zoning
termKept in this browser · My desk
A method of emission security that classes a site by its equivalent free-space attenuation up to the boundary of the area the organization controls, and requires devices whose emissions are low enough for that zone.
Germany's Federal Office for Information Security (BSI) runs the National Zoning Model of Emission Security: buildings and properties are divided into zones by their attenuation of electromagnetic radiation, devices into matching classes, and the two belong inseparably together. Distances express the equivalent free-space attenuation to the controlled boundary. For information up to GEHEIM (SECRET), zone 0 (more than 8 up to 20 m) needs a Level A device, zone 1 (more than 20 up to 100 m) a Zone 1 device, zone 2 (more than 100 up to 1,000 m) a Zone 2 device, and zone 3 (more than 1,000 m) a Zone 3 device; up to VS-VERTRAULICH each requirement drops one class. Only metallic components shield efficiently; masonry, glass, concrete, stone, plaster and wood are no significant obstacle.
What is measured. Germany's Federal Office for Information Security (BSI) states the aim from the attacker's side: keep the reception level an attacker could achieve at the perimeter below a maximum. Equivalent free-space attenuation is the loss a signal would suffer over the stated distance in open space, or the loss the surroundings (a building, a cabin) impose that reduces the level just as much. The distances are set by the controlled area: where a sole-use property has no fence, the building's outer walls are the boundary. A controlled area that does not contain a sphere of at least 8 metres around the device is a particularly high-risk case that the BSI decides individually, and an equivalent attenuation of 1,000 metres or more, as in a bunker or a shielding enclosure, makes the site zone 3.
A worked case. An office handling SECRET material whose controlled boundary is equivalent to 60 metres of free space is in zone 1 and needs at least a Zone 1 device. The same office with only a masonry wall between the equipment and a public corridor 15 metres away falls into zone 0, because the wall adds almost nothing, and needs a Level A device, whose emissions must be very low both in free space and on cables, which the BSI notes shows in the price. Zone 3 requirements are met by many unmodified commercial devices. In the BSI's glossary a Zone 1 device is approved for zones 1 to 3, a Zone 2 device for zones 2 and 3, a Zone 3 device for zone 3 only, and cryptographic hardware generally has to meet the Level A requirements.
What breaks a zone. Cables. Electromagnetic radiation couples onto metal and travels along it with very little loss, so power cables, air-conditioning ducts and heating, cooling or water pipes act as random conductors that enormously increase the range; the BSI therefore requires sole control over that infrastructure in the whole controlled area. An agency that shares a building with others does not have it, and must either use Level A devices with the model's minimum distances and installation rules or put Zone 1, 2 or 3 devices in a shielding enclosure that filters every outgoing line, power and data alike. Changes break the device side: the BSI tests a reference device of each model in a usable configuration under real conditions, then every unit produced with a survey method, and treats a device set (computer, screen, mouse and keyboard) as one unit; adding a second monitor, a webcam or a headset, replacing a keyboard or repairing the device voids the approval, and classified processing must stop until a new test. The model covers stationary installations only; mobile use is examined case by case.
The same idea elsewhere. The United States (US) version is older. National Security Telecommunications and Information Systems Security Advisory Memorandum (NSTISSAM) TEMPEST/2-95 of 1995 describes TEMPEST zoning as a countermeasure that exploits free-space propagation loss and a building's own shielding, profiled under NSTISSAM TEMPEST/2-92 by measuring the attenuation of radiated signals in four test bands between 10 and 1,000 MHz against reference measurements with antennas 20 metres apart in open field. Facilities fall into zones A, B and C, or, if never measured, are judged by the inspectable space around them (under 20 metres, 20 to 100 metres, over 100 metres), with extra precautions below 8 metres or where a wall is shared with uninspectable space; equipment gets zones A to D by comparison with the Level I, II and III limits of TEMPEST/1-92, and a mixed system is installed to the rules of its worst unit. The thresholds of 8, 20 and 100 metres recur in the BSI's bands. The European Union (EU) bases TEMPEST protection on facility zoning under its Information Assurance Security Guidelines (IASG) 7-02 and equipment testing under IASG 7-03, with levels A, B and C, or on operating systems in a shielded enclosure; the United Kingdom's National Cyber Security Centre (NCSC) applies the North Atlantic Treaty Organization (NATO) documents SDIP-27 and SDIP-29.
Why it works. It turns emission security into a budget: distance the organization controls is the cheapest shield, metal is the next, and device hardening covers the rest. Every device, whatever its class, must pass an emission test before classified processing begins; the BSI's Technical Guideline TR-03209 gives the details, and its TL-03305 lists name the tested devices.
Also known as: National Zoning Model of Emission Security, zone model (emission security), Zonenmodell, zoneamento de segurança de emissões
Sources
- BSI, The National Zoning Model of Emission Security (read 2026-11-23): zones by equivalent free-space attenuation to the boundary of the controlled area; only metallic components shield; masonry, glass, concrete are no significant obstacle; BSI TR-03209
- BSI, Availability of shielded devices (read 2026-11-23): table of minimum device classes by zone for GEHEIM and VS-VERTRAULICH; Zone 0 (>8) to 20 m, Zone 1 >20 to 100 m, Zone 2 >100 to 1,000 m, Zone 3 >1,000 m
- BSI, Division of buildings and properties into zones (read 2026-11-23): equivalent distances set by the controlled area; the outer walls delimit it where there is no fence; a controlled area without a sphere of at least 8 m radius is a high-risk case decided individually by the BSI; 1,000 m or more (bunker, shielding enclosure) means zone 3; power cables, air-conditioning ducts and metal pipes act as random conductors; sole control of the infrastructure, otherwise Level A devices or devices in a filtered shielding enclosure
- BSI, Emission security glossary (read 2026-11-23): TEMPEST is a code name, not an acronym, used both for the protective measures and the attack methods; EMSEC; a device set (computer, screen, mouse and keyboard) is tested and used as a unit; Level A devices process GEHEIM in zone 0, as cryptographic hardware generally must; Zone 1, 2 and 3 devices approved for zones 1 to 3, 2 and 3, and 3; the BSI is Germany's National TEMPEST Authority
- BSI, Emission tests for devices (read 2026-11-23): an approval measurement of a reference device in a usable configuration under real conditions, then a survey measurement method for the device type; every device produced to process classified information must pass
- BSI, Follow-on modifications to a shielded device (read 2026-11-23): a second monitor, webcam or headset, a replaced keyboard or monitor, a repair or any change voids the assured emission characteristics; processing of VS-VERTRAULICH or higher must cease until a new emissions test
- BSI, Mobile deployment of IT devices (read 2026-11-23): the national zoning model is set up for stationary deployment; mobile use of classified-processing devices is not regulated by it and is examined case by case
- NSTISSAM TEMPEST/2-95, RED/BLACK Installation Guidance, National Security Telecommunications and Information Systems Security Committee, 12 December 1995, released by the NSA on a FOIA appeal and published by Cryptome on 30 December 2000 (read 2026-11-23): supersedes NACSIM 5203 of 30 June 1982; definitions of RED and BLACK equipment, the RED/BLACK concept, compromising emanations, inspectable space, equipment and facility TEMPEST zones; physical and electrical separation; 100, 80 and 60 dB isolation; Table 3-1 separations of 50 cm and 1 m for processors and 5 cm (15 cm for parallel runs over 30 m) for lines; shielded cables and optical fibre; facility zoning in four bands from 10 to 1,000 MHz against a 20 m open-field reference; no commitment of funds without CTTA concurrence
- Council of the European Union, doc. 7887/19, Information Assurance Security Guidelines on Accreditation of EU TEMPEST Companies (IASG 7-04), approved by the Council Security Committee on 22 March 2019, replacing doc. 16267/12 (read 2026-11-23): TEMPEST protection rests on facility zoning (IASG 7-02) and equipment testing (IASG 7-03, levels A, B and C) or on operating systems in a shielded enclosure (IASG 7-01); National TEMPEST Authorities; level A and B equipment subject to proliferation rules outside the EU
- National Cyber Security Centre (UK), TEMPEST and EMS Policy (read 2026-11-23): its TEMPEST and electromagnetic security documents are based on NATO and EU standards; Implementation Guide 14 (issue 3.0, 2018) interprets SDIP-27 for UK use, with SDIP-27 and SDIP-29 produced by SECAN; Good Practice Guide 14, issue 2.3, September 2016